Ünmak UKYS/3G series solid fuel boilers are designed to burn coal and wood. The shape is cylindrical and it has three pass. On demand the boiler can modify so that burn liquid fuel and gas. They have different capacities with high efficiency. The boilers are user friendly and provide comfortable heating.
- Boiler outlet
- Safety outlet
- Chimney
- Water filling - Discharge
- Fan
- Boiler inlet
- Safety inlet
- Ash discharge cover
- Fuel entry cover
- Observing glass
- Flue pipes cleaning cover
- Control board
MODEL |
ÜKYS/3G |
120 |
150 |
180 |
210 |
240 |
270 |
300 |
330 |
360 |
390 |
420 |
450 |
480 |
510 |
540 |
600 |
660 |
720 |
780 |
840 |
900 |
1000 |
1100 |
1200 |
Fuel Type |
Wood- Coal- Biomass |
Heat Output |
kw |
140 |
174 |
209 |
244 |
279 |
314 |
349 |
384 |
419 |
453 |
488 |
523 |
558 |
593 |
628 |
698 |
767 |
837 |
907 |
977 |
1047 |
1163 |
1279 |
1395 |
kcal/h |
120000 |
150000 |
180000 |
210000 |
240000 |
270000 |
300000 |
330000 |
360000 |
390000 |
420000 |
450000 |
480000 |
510000 |
540000 |
600000 |
660000 |
720000 |
780000 |
840000 |
900000 |
1000000 |
1100000 |
1200000 |
Burning Chamber Height |
mm |
450 |
485 |
500 |
540 |
560 |
595 |
605 |
Burning Chamber Width |
mm |
655 |
700 |
750 |
800 |
815 |
850 |
895 |
Burning Chamber Lenght |
mm |
1100 |
1330 |
1510 |
1680 |
2030 |
Burning Chamber Volume |
dm3 |
324 |
373 |
413 |
575 |
607 |
764 |
850 |
1099 |
Fuel Entry |
mm |
380*345 |
430*395 |
460*415 |
500*435 |
520*435 |
Water Volume |
lt |
720 |
794 |
894 |
1146 |
1276 |
1213 |
1768 |
1814 |
1905 |
1987 |
2063 |
2433 |
2369 |
2628 |
2678 |
2585 |
2915 |
3093 |
3248 |
3448 |
3354 |
4396 |
4479 |
4610 |
Boiler Weight |
kg |
1270 |
1375 |
1610 |
1740 |
1925 |
2000 |
2450 |
2615 |
2740 |
2830 |
3100 |
3250 |
3335 |
3585 |
3700 |
3860 |
4135 |
4350 |
4490 |
4740 |
5020 |
5600 |
5890 |
6250 |
Required Draft |
mbar |
0,42 - 0,45 |
0,44 - 0,47 |
0,46 - 0,49 |
0,48 - 0,52 |
0,51 - 0,54 |
0,53 - 0,57 |
0,56 - 0,59 |
Min-Max Operating |
°C |
45-85 |
Water Return Temperature (Recommended) |
°C |
35 |
Maximum Operating Pressure |
bar |
4 |
Test Pressure |
bar |
6 |
Width(a) |
mm |
1200 |
1240 |
1320 |
1428 |
1510 |
1580 |
1600 |
1650 |
1700 |
1790 |
1810 |
1890 |
1950 |
2000 |
2050 |
2100 |
2150 |
Lenght(b) |
mm |
2220 |
2690 |
2920 |
3020 |
3540 |
Chimney Connection Height (b) |
mm |
1145 |
1120 |
1300 |
1315 |
1370 |
1415 |
1440 |
1475 |
1485 |
1480 |
1575 |
1615 |
1640 |
1570 |
1655 |
1645 |
1700 |
1750 |
1760 |
1815 |
1860 |
Boiler Total Height(h) |
mm |
1570 |
1610 |
1690 |
1798 |
1880 |
1950 |
1970 |
2020 |
2070 |
2160 |
2180 |
2260 |
2320 |
2370 |
2420 |
2470 |
2520 |
Exhaust Gas Connection Diameter (Chimney) |
mm |
300 |
300 |
350 |
400 |
Min-Max Flue Temperature |
°C |
170-210 |
Boiler Outlet-Inlet |
R'' |
DN 50 |
DN 65 |
DN 80 |
DN 100 |
DN 125 |
DN 150 |
Expansion Tank Outlet-Inlet |
R'' |
1 1/4'' |
1 1/2'' |
2'' |
2 1/2'' |
Filling - Discharge |
R'' |
3/4'' |
Electrical Connection |
V/Hz |
230V - 50 Hz |
*The right to make changes in dimension is reserved.