ÜNMAK ÜKY/DUO three-pass heating boilers produced with superior technology comply with EN 303-5 Standard. The special cast iron crucible (furnace) design makes it suitable for burning all kinds of domestic and foreign lignite, and the water pipe grill makes it possible to burn logs and provide full burning.
It is designed to burn coals known as solid coal, double fuel, between 10 and 25 mm on the market, known as rice coal, hazelnut coal, in the pot. Block wood can be burned on special high-carbon pipes on the ladle, acting as a grid.
It provides healthy burning with automatic fuel loading. Since it loads according to the thermal need, excess fuel in the combustion chamber is prevented.
When there is no coal to burn in the combustion pot, the wood can be burned with manual use by loading the wood manually on the water contained grid.
It has a compact structure with its prismatic body, making it easy to be mounted in narrow spaces.
Thanks to its three-pass structure, it increases the surface of transferring heat energy from smoke to water and reduces emissions.
It provides convenience in cleaning and chimney draft with its sliced (water jacketed-buffer) structure.
It provides more precise thermostat control with its digital control panel. It allows intervention to loading settings according to fuel quality, and sends the most appropriate amount of fuel to the combustion chamber. When it reaches the set temperature, it stops the fuel supply and the fan, and when the temperature drops, it takes these parts again and continues heating from where it left off.
Thanks to the fan, it reaches the set temperature faster and provides combustion optimization.
With the option of connecting the room thermostat, the comfort of adjusting the boiler water temperature remotely is provided.
Thanks to the heat insulated body, keeping the temperature emitted from the boiler surface inside saves fuel.
If the outside temperature is high, the boiler can be closed from the control panel. In this case, the burning of the fan is darkened when the fan shuts down and the burning is delayed. When the need for heat arises again, the boiler is opened from the control panel and continues to burn without the need for ignition and reaches the desired temperature in a short time (burning delay can be done up to 24 hours depending on the coal quality).
Thanks to its automatic stop feature, the control panel detects when the fuel runs out; fan and circulation pump stop automatically. This feature saves energy.
Thanks to easy-to-use, large filling, cleaning between slices and ash extraction covers, fuel filling, ignition, ash removal between slices can be done easily.
Its elegant appearance and protection against rusting is provided by covering the body plates coated outside of the boiler with electrostatic powder paint. Boiler surfaces are protected with special wet paint.
It provides the opportunity to obtain hot water with the addition of water storage tank.
1. Control panel |
9. Safety flow line |
2. Log wood feeding cover |
10. Filling/Discharging |
3. Ash cleaning cover |
11. Safety return line |
4. Fan |
12. Boiler flow line |
5. Fuel hopper (Bunker) |
13. Flue |
6. Gearmotor |
14. Water grid for wood |
7. Auger shaft |
15. Ashtray |
8. Boiler return line |
16. Firepot |
MODEL - SERIES: ÜKY/DUO |
25 |
40 |
60 |
80 |
100 |
Fuel Type |
Wood - Coal |
Heating Power |
kW |
29 |
46 |
70 |
93 |
116 |
kcal/h |
25.000 |
40.000 |
60.000 |
80.000 |
100.000 |
Firepot Diameter |
mm |
290 |
340 |
400 |
Fuel Capacity |
Coal |
kg |
120 |
150 |
190 |
Pomace |
kg |
105 |
125 |
160 |
Fuel Feeding Cover |
mm |
200x355 |
200x405 |
200x500 |
190x585 |
Combustion Chamber Depth |
mm |
475 |
640 |
850 |
920 |
Water Volume |
lt |
80 |
115 |
150 |
210 |
255 |
Boiler Weight |
kg |
320 |
360 |
460 |
595 |
705 |
Required Draft in Chimney |
Pa |
25-28 |
28-31 |
31-33 |
33-35 |
35-40 |
Temperature Control Range |
°C |
40-80 |
Recommended Return Temp. |
°C |
40 |
Max. Operating Pressure |
bar |
3 |
Test Pressure |
bar |
5 |
Dimensions |
a |
mm |
515 |
565 |
662 |
780 |
b |
mm |
880 |
1050 |
1265 |
1335 |
c |
mm |
730 |
800 |
d |
mm |
1200 |
1250 |
e |
mm |
600 |
770 |
980 |
1055 |
f |
mm |
1375 |
1450 |
g |
mm |
1100 |
1090 |
1180 |
1300 |
h |
mm |
1495 |
1570 |
Flue Diameter |
mm |
130 |
180 |
220 |
Min-Max. Flue Temperature |
°C |
170 - 210 |
Boiler Flow-Return Pipes |
R" |
1" |
1 ¼" |
1 ½" |
2" |
Safety Flow Return Pipes |
R" |
1" |
1½" |
Filling/Discharging Pipes |
R" |
½" |
3/4" |
Electricity Connection |
V/Hz |
230/50 |
* The right t
o make changes in dimension is reserved.