UKYP Series Central Heating Prismatic Boilers
Product Code: ÜKYP

 Ünmak UKYP series prismatic solid fuel Boilers are designed to burn coal and wood. They have eleven different capacities. Boilers are user friendly and provide comfortable heating. 

 

  1. Boiler Outlet
  2. Safety Outlet
  3. Flue Box
  4. Boiler Inlet
  5. Safety Inlet
  6. Fan and fan flap
  7. Water Filling - Discharge  
  8. Ash discharge cover
  9. Fuel entry cover
  10. Observing glass
  11. Flue pipes cleaning cover
  12. Control board
MODEL ÜKYP 130 160 180 200 250 300 350 400 450 500 600
Fuel Type Wood - Coal - Biomass
Heat Output kW 151 186 209 233 291 349 407 465 523 582 698
kcal/h 130.000 160.000 180.000 200.000 250.000 300.000 350.000 400.000 450.000 500.000 600.000
Burning Chamber Height mm 510 560
Burning Chamber Width mm 600 700 800 755 790
Burning Chamber Lenght mm 1020 1220 1320 1045 1400 1510
Burning Chamber Volume dm3 312 373 436 471 539 402 462 619 668
Fuel Entry mm 440*340 460*380
Water Volume lt 320 400 480 560 640 890 925 1240 1195 1505 1570
Boiler Weight kg 740 855 985 1050 1205 1595 1745 1960 2015 2305 2560
Requird Draft mbar 0,42 - 0,45 0,44 - 0,47 0,45 - 0,49 0,47 - 0,51 0,50 - 0,53
Min-Max Operating Temperature C 45-85
Water Return Temperature (Recommended) C 35
Maximum Operating Pressure bar 3
Test Pressure bar 5
Width (a) mm 760 860 960 1130 1180 1390
Lenght (b) mm 1615 1815 1915 2280 2400 2750
Chimney Connection Height (c) mm 1370 1465 1600 1665 1675
Boiler Total Height (h) mm 1640 200 2055 2095 2125
Exhaust Gas Connection Diameter (Chimney) mm 220 300 350
Min - Max Flue Temperature C 170 - 210
KBoiler Outlet - Inlet R" 2" 2 1/2" DN80 DN100 DN125
Expansion Tank Outlet-Inlet R" 1 1/2" 2"
Filling - Discharging R" 3/4" 3/4"
Electrical Conneciton V/Hz 230 V - 50 Hz

*The right to make changes in dimension is reserved.