ÜKYS/3G-Y Series Central Heating Automatic Loading Cylindrical Boilers
Product Code: ÜKYS/3G-Y

ÜNMAK ÜKYS / 3G-Y three-pass heating boilers produced with superior technology comply with EN 303-5 and TS 497 Standards. The special cast iron crucible (furnace) design makes it suitable for burning any type of domestic and foreign lignite and ensures complete combustion.

It is designed to burn solid fuel, between 10 and 25 mm, known as rice coal, hazelnut coal.

It provides healthy burning with automatic fuel loading. Since it loads according to the thermal need, excess fuel in the combustion chamber is prevented.

It has a compact structure with its prismatic body, making it easy to be mounted in narrow spaces.

Thanks to its three-pass structure, it increases the surface of transferring heat energy from smoke to water and reduces emissions.

The heat transfer surface area is increased with the flame smoke pipes, thus the efficiency is increased.

It provides more precise thermostat control with its digital control panel. It allows intervention to loading settings according to fuel quality, and sends the most appropriate amount of fuel to the combustion chamber. When it reaches the set temperature, it stops the fuel supply and the fan, and when the temperature drops, it activates these parts again and continues the heating from where it left off.

Thanks to the fan, it reaches the set temperature faster and provides combustion optimization.

With the option of connecting the room thermostat, the comfort of adjusting the boiler water temperature remotely is provided.

Thanks to the heat insulated body, keeping the temperature emitted from the boiler surface inside saves fuel.

If the outside temperature is high, the boiler can be closed from the control panel. In this case, the burning of the fan is darkened when the fan shuts down and the burning is delayed. When the need for heat arises again, the boiler is opened from the control panel and continues to burn without the need for ignition and reaches the desired temperature in a short time (burning delay can be done up to 24 hours depending on the coal quality).

Thanks to its automatic stop feature, the control panel detects when the fuel runs out; fan and circulation pump stop automatically. This feature saves energy.

Fuel filling, ignition, ash removal and pipe cleaning can be done easily thanks to the easy-to-use large filling, pipe cleaning and ash removal covers.

Its elegant appearance and protection against rusting is provided by covering the body plates coated outside of the boiler with electrostatic powder paint. Boiler surfaces are protected with special wet paint.

It provides the opportunity to obtain hot water with the addition of hot water storage tank.

 

  1. Boiler outlet
  2. Safety outlet
  3. Chimney
  4. Boiler inlet
  5. Safety inlet
  6. Water Filling - sidcharge
  7. Ash dischrage cover 
  8. Observing glass
  9. Flue pipes cleaning cover 
  10. Fuel entry cover
  11. Control board
  12. Bunker
  13. Reducer
  14. Bunker desk
  15. Spiral
  16. Pot
  17. Fan
MODEL ÜKYS/3G/Y 120 150 180 210 240 270 300 330 360 390 420 450 480 510 540 600 660 720 780 840 900 1000 1100 1200
Fuel Type Coal - Prina - Pellet -Shell - Nuts
Heat Output kw 140 174 209 244 279 314 349 384 419 454 488 523 558 593 628 698 768 837 907 977 1047 1163 1279 1396
kcal/h 120000 150000 180000 210000 240000 270000 300000 330000 360000 390000 420000 450000 480000 510000 540000 600000 660000 720000 780000 840000 900000 1000000 1100000 1200000
Pot Dimensions mm 430*410 640*810 690*1000 740*1000
Fuel Capacity Kömür kg 250 300 350 450
Prina kg 213 255 299 383
Water Volume lt 720 794 894 1146 1276 1213 1768 1814 1905 1987 2063 2433 2369 2628 2679 2585 2915 3093 3248 3448 3354 4396 4479 4610
Boiler Weight kg 1420 1525 1760 1890 2075 2150 2600 2765 2890 2980 3250 3400 3485 3735 3850 4010 4285 4500 4640 4890 5170 5750 6040 6400
Required Draft mbar 0,42 - 0,45 0,44 - 0,47 0,46 - 0,49 0,48 - 0,52 0,51 - 0,54 0,53 - 0,57 0,56 - 0,59
Min-Max Operating Temperature °C 45-85
Water Return Temperature °C 35
Maximum Operating Pressure bar 4
Test Pressure bar 6
Boiler Total Height(a) mm 2100 2140 2220 2328 2410 2480 2600 2650 2740 2760 2810 2890 2950 3000 3050 3100
Lenght(b) mm 2220 2690 2920 3020 3540
Body Width (c) mm 1200 1240 1320 1428 1510 1580 1600 1650 1700 1790 1810 1890 1950 2000 2050 2100 2150
Chimney Connection Height (b) mm 1145 1120 1300 1315 1370 1415 1440 1475 1485 1480 1575 1615 1640 1570 1655 1645 1700 1750 1760 1815 1860
Spiral Dissemble distance (e) mm 1550 1600 1860 1900 1950
Boiler total height (h) mm 1570 1610 1690 1798 1880 1950 1970 2020 2070 2160 2180 2260 2320 2370 2420 2470 2520
Exhaust Gas Connection Diameter (Chimney) mm 300 300 350 400
Min-Max Flue Temperature °C 170-210
Boiler Outlet - Inlet R'' DN 50 DN 65 DN 80 DN 100 DN 125 DN 150
Exspansion Tank Outlet-Inlet R'' 1 1/4'' 1 1/2'' 2'' 2 1/2''
Filling - Discharge R'' 3/4''
Electrical connection V/Hz 230V - 50 Hz

*The right to make changes in dimension is reserved.